EasyManua.ls Logo

Siemens SITRANS F US - Page 144

Siemens SITRANS F US
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
142 Hardware Installation Manual, 11/2015, A5E34981613-AC
C1 Energy Total
30207
4
Real
Analog_In
8
Float
129
43-2Bh
ADF(Float)
3
1
C1 EnergyTotal
Units
30661 8 String String_In 8 UINT16 131 43-2Bh BD(Byte) 17 8
C1 Inst.Flow
Rate
30109 4 Real Analog_In 9 Float 129 6-06h ADF(Float) 4 1
C1 Avg Flow
Rate
30121 4 Real Analog_In 10 Float 129 1-01h P ADF(Float) 5 1
C1 Flow Rate
Units
30517 8 String String_In 12 UINT16 131 1-01h BD(Byte) 25 8
C1 Raw Flow
30133
4
Real
Analog_In
11
Float
n/a
ADF(Float)
6
1
C1 Raw Flow
Units
30537 8 String String_In 16 UINT16 n/a BD(Byte) 33 8
C1 Total 30145 4 Real Analog_In 12 Float 129 34-22h ADF(Float) 7 1
C1 Total Units
30557
8
String
String_In
20
UINT16
131
34-22h
BD(Byte)
41
8
C1 Sonic Vel
30157
4
Real
Analog_In
13
Float
n/a
ADF(Float)
8
1
C1 Sonic Vel
Units
30577 8 String String_In 24 UINT16 n/a BD(Byte) 49 8
C1 Supply Temp
30303
4
Real
Analog_In
14
Float
n/a
ADF(Float)
9
1
C1 Supply Temp
Units
30773 8 String String_In 28 UINT16 n/a BD(Byte) 57 8
C1 Return Temp
30309
4
Real
Analog_In
15
Float
n/a
ADF(Float)
10
1
C1 Return Temp
Units
30781 8 String String_In 32 UINT16 n/a BD(Byte) 65 8
C1 Temp Diffe-
rence
30315 4 Real Analog_In 16 Float n/a ADF(Float) 11 1
C1 Temp Diff
Units
30789 8 String String_In 36 UINT16 n/a BD(Byte) 73 8
C1 Signal
Strength
30167 2 Integer Analog_In 17 Float n/a ADF(Float) 12 1
C1 Sig Strength
Units
30593 8 String String_In 40 UINT16 n/a BD(Byte) 81 8
C1 Aeration
30172
2
Integer
Analog_In
18
Float
n/a
ADF(Float)
13
1
C1 Aeration Units
30609
8
String
String_In
44
UINT16
n/a
BD(Byte)
89
8
C1 Status
/Alarms: Spacing
10021 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 1 1
C1 Status
/Alarms: Empty
10022 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 3 1
C1 Status
/Alarms: Rate
10023 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 4 1
C1 Status
/Alarms: Fault
10024 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 5 1
C1 Status
/Alarms: Aeration
10025 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 6 1
C1 Status
/Alarms: Memory
10026 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 7 1
C1 Status
/Alarms: Makeup
10027 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 8 1
C1 Status
/Alarms: Interface
10028 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 9 1

Table of Contents