Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
170 Hardware Installation Manual, 11/2015, A5E34981613-AC
Status: Memory
Path 4
10086 1 Bit Coil Binary_In 3 UINT16 n/a DI(Dig In) 37 1
Status: Makeup
Path 4
10087 1 Bit Coil Binary_In 3 UINT16 n/a DI(Dig In) 38 1
Status: Interface
Path 4
10088 1 Bit Coil Binary_In 3 UINT16 n/a DI(Dig In) 39 1
Status: Pig
Path 4
10089 1 Bit Coil Binary_In 3 UINT16 n/a DI(Dig In) 40 1
Status: Zeromatic
Path 4
10090 1 Bit Coil Binary_In 3 UINT16 n/a DI(Dig In) 32 1
Status/Alarms:
Spacing
10001 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 41 1
Status/Alarms:
Empty
10002 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 43 1
Status/Alarms:
Rate
10003 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 44 1
Status/Alarms:
Fault
10004 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 45 1
Status/Alarms:
Aeration
10005 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 46 1
Status/Alarms:
Memory
10006 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 47 1
Status/Alarms:
Makeup
10007 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 48 1
Status/Alarms:
Interface
10008 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 49 1
Status/Alarms:
Pig
10009 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 50 1
Status/Alarms:
Zeromatic
10010 1 Bit Coil Binary_In 4 UINT16 n/a DI(Dig In) 42 1
Temperature 1
30293
4
Real
Analog_In
35
Float
n/a
ADF(Float)
30
1
Temperature 2
30295
4
Real
Analog_In
36
Float
n/a
ADF(Float)
31
1
Temp Units
30753
8
String
String_In
60
UINT16
n/a
BD(Byte)
121
8
Delta Time
Path 1
30179 4 Real Analog_In 37 Float n/a ADF(Float) 32 1
Delta Time
Path 2
30181 4 Real Analog_In 38 Float n/a ADF(Float) 33 1
Delta Time
Path 3
30183 4 Real Analog_In 39 Float n/a ADF(Float) 34 1
Delta Time
Path 4
30185 4 Real Analog_In 40 Float n/a ADF(Float) 35 1
Delta Time Units
30629
8
String
String_In
64
UINT16
n/a
BD(Byte)
129
8
Analog Input 1
30277
4
Real
Analog_In
41
Float
n/a
ADF(Float)
36
1
AI1 Units
30797
8
String
String_In
68
UINT16
n/a
BD(Byte)
137
8
Analog Input 2
30279
4
Real
Analog_In
42
Float
n/a
ADF(Float)
37
1
AI2 Units
30801
8
String
String_In
72
UINT16
n/a
BD(Byte)
145
8
Analog Input 3
30281
4
Real
Analog_In
43
Float
n/a
ADF(Float)
38
1
AI3 Units
30805
8
String
String_In
76
UINT16
n/a
BD(Byte)
153
8
Analog Input 4
30283
4
Real
Analog_In
44
Float
n/a
ADF(Float)
39
1