SITRANS FUS080 transmitter
Operating Instructions, 07/2012, A5E03059912-02
45
Functions
7
7.1 Unit selection
The device is delivered with totalizer and flow rate units in m and m
3
/h, respectively, as
standard. However, it is possible to manually configure the device to operate with other units.
Changing the units
Go via PDM menu "Device" → "Unit guide". Select the new unit from the list and click on
"Apply Change of Units". The change should be stored into the transmitter via "Device" →
"Download to Device" afterwards
.
Figure 7-1 Unit selection
Note
The display is only able to show m
3
and m
3
/h
If the units are changed to units other than m
3
and m
3
/h, the display will not show any unit
indication after the measured value on the display. To show the new customer unit on the
display, a sticker can be used to show units. This sticker should be affixed to the transmitter
display.
7.2 Number of decimal digits
For the display values (totalizers in menu 1 and 2 and flow in menu 3) "Auto adjust decimal
point" is the default setting. This means that the number of digits after the decimal point
automatically will be reduced with increasing number of digits before the decimal point.