Settings
B.2 Factory settings for MODBUS communication
SITRANS FUS080 transmitter
84 Operating Instructions, 07/2012, A5E03059912-02
Totalizer directions
Totalizer 1 direction Forward Forward Forward/Reverse/Forward
net/Reverse net
Totalizer 2 direction Reverse Reverse Forward/Reverse/Forward
net/Reverse net
Digital output 1
Active On On On/off
Direction Forward Forward Forward/Reverse/Forward
net/Reverse net
Amount per pulse 0.1m
3
0.1 m
3
Unit: The same as Totalizer
unit
Value freely selectable
Pulse width 5 ms 5 ms 5, 10, 20, 50, 100, 200, 500
ms
Digital Output 2
Active On On On/off
Function Alarm Alarm Pulse/Alarm/Call up
Direction No influence, while "Alarm" No influence, while "Alarm" Forward/Reverse/Forward
net/Reverse net
Amount per pulse No influence, while "Alarm" No influence, while "Alarm" Unit: The same as Totalizer
unit
Value freely selectable
Pulse width No influence, while "Alarm" No influence, while "Alarm" 5, 10, 20, 50, 100, 200, 500
ms
B.2 Factory settings for MODBUS communication
Parameter Default setting
Slave device address 1
Data transmission rate 19 200
Vertical parity position E-8-1 (0 - even)
Response timeout 10000 ms
Response delay 1 ms
Interframe space 35
The settings can be changed via SIMATIC PDM or via the MODBUS.