Nominal size *) Max. vol. flow Pipe diameter Path angle Path length
[mm] [inch] [m3/h] [m] [º] [m]
DN 100 4 100 0.1071 45 0.1795
DN 125 5 150 0.1317 45 0.2143
DN 150 6 220 0.1593 45 0.2533
DN 200 8 380 0.2083 60 0.2584
DN 250 10 600 0.2604 60 0.3185
DN 300 12 850 0.3098 60 0.3756
DN 350 14 1000 0.3396 60 0.4100
DN 400 16 1300 0.3904 60 0.4687
DN 450 18 1700 0.4500 60 0.5375
DN 500 20 2200 0.4920 60 0.5860
DN 550 22 2600 0.5500 60 0.6529
DN 600 24 3200 0.6016 60 0.7125
DN 650 26 3600 0.6500 60 0.7684
DN 700 28 4200 0.6952 60 0.8206
DN 750 30 4800 0.7500 60 0.8839
DN 800 32 5500 0.7968 60 0.9379
DN 900 36 7500 0.9100 60 1.0686
DN 1000 40 9000 1.0000 60 1.1726
DN 1100 44 10000 1.1000 60 1.2880
DN 1200 48 13200 1.2000 60 1.4035
DN 1300 52 14000 1.3000 60 1.5190
DN 1400 56 16800 1.4000 60 1.6344
DN 1500 60 19000 1.5000 60 1.7499
DN 1600 64 22800 1.6000 60 1.8654
DN 1700 68 25000 1.7000 60 1.9808
DN 1800 72 27600 1.8000 60 2.0963
DN 1900 76 31000 1.9000 60 2.2118
DN 2000 80 36000 2.0000 60 2.3273
DN 2100 84 37000 2.1000 60 2.4427
DN 2200 88 42000 2.2000 60 2.5582
DN 2300 92 45000 2.3000 60 2.6737
DN 2400 96 51000 2.4000 60 2.7891