Weighing Functions
SIWAREX FTA
Range of Values / Explanation
weightings
Number of weighing procedures (with and
without tolerance check)
Number of weighing procedures with
tolerance check
procedures over TO2
Number of weighing procedures with
tolerance check over tolerance limit TO2
No. weigh procedures over
TO1
Number of weighing procedures with
tolerance check over tolerance limit TO1
procedures good
Number of weighing procedures with
tolerance check within tolerance limits TU1
No. weigh procedures
under TU1
Number of weighing procedures with
tolerance check under tolerance limit TU1
under TU2
Number of weighing procedures with
tolerance check under tolerance limit TU2
procedures bad
Number of weighing procedures with
tolerance check outside tolerance limits TU2
Current set weight (calibratable numeral
step,
with AWI application and country code
“OIML” rounded to the corresponding
Average value of net
weight
Average value of the net weights checked
for tolerance errors
Standard deviation of net
weights
Standard deviation of the net weights
checked for tolerance errors
Performance per hour [e.g. g/h, kg/h or t/h]
is projected based on the net weight of the
hour
Weighing procedures per hour projected
based on the last weighing procedure (time
Table 5-22 DR 32 Allocation
5.21.1 DR 32 - Total number of weighing procedures
Number of weighings since the last statistic data deletion. The number of single fills
is determined in all operating modes.
5.21.2 DR 32 - Number of control weighs
The number of weighings in which a tolerance check has been performed. In
operating modes with totalizing (AWI totalizing and AWI gravimetric big bag),