Hardware Planning and Assembly
SIWAREX FTA
4.5.15 LED Indicators
SF Red LED 1 upper
Hardware fault
Weighing cycle active (flashing)
Green LED 3
Write protect for calibration data
activated
Green LED 6
Micro Memory Card is operation
ready
SEN Green LED 8
Supply voltage feedback from
load cells
Table 4-13 Indicators (LED)
4.5.16 Using the Micro Memory Card
A SIMATIC Micro Memory Card can be used for saving the calibratable records or
for recording weighing states. Approximately 32 MB of data can be stored on the
MMC described in chapter Accessories.
Warning notice
After formatting the MMC with SIWAREX FTA, it can no longer be used in the
SIMATIC CPU. Therefore, the MMC should be labelled correspondingly.