Weighing Functions
SIWAREX FTA
Table 5-15 Tolerance information evaluation
5.16 DR 23 Scale parameter 2 (AWI)
Weighing parameters are held in DR23. These are normally typical to the scale
and do not depend heavily on the changing material properties within a limited
extent. Procedure:
o Adjust all parameters corresponding to their purpose
o Send DR 23 to the scale
o If required, check parameters using tests
Range of Values / Explanation
automatic logging
0: No autom. logging after the
weighing procedure
1: autom. logging with text 1
2: autom. logging with text 2
3: autom. logging with text 3
4: autom. logging with text 4
Other definitions not permitted.
value filter for dosing
0: average value filter deactivated
Other definitions not permitted.
Wizzard:
Maximum set weight for a single
After switching the coarse signal on, no weight
evaluation is performed for the defined amount of
After switching the coarse signal off, no weight
evaluation is performed for the defined amount of
comparison
After the command for starting the inhibition time,
the actual weight is not monitored during the
weighing procedure for the defined amount of
output with coarse
Analog output value if coarse signal active (in %)
output with fine
Analog output value if fine signal active (in %)
Status output condition
TO2 TO1 Good TU1 TU2 Off
Net weight from TU1 to TO1 0 0 1 0 0 0
Net weight above TO1 to TO2 0 1 0 0 0 0
Net weight above TO2 1 0 0 0 0 1
Net weight from TU2 to under TU1 0 0 0 1 0 0
Net weight under TU2 0 0 0 0 1 1