Programming in SIMATIC STEP 7
SIWAREX FTA
8-168
Image 8-2 Calibratable display in TP/OP
8.6.2 Installation and Project Planning for the Calibratable Weight Display
First, the OCX add-on for secure output (SecureOCX) must be integrated into the
setup environment of WinCC flexible. There are three different program versions
for WinCC flexible 2005 (valid as of version WinCC flexible 2005 SP1 HF6), and
WinCC flexible 2007 and WinCC flexible 2008.
The corresponding software is created in the respective configuration package in
the directory OCX_FOR_SECURE_DISPLAY_WinCC_....
For the installation of the SecureOCX for WinCC flexible 2008 SP3 follow the
instructions of the readme file in the software directory. For all other versions the
installation is described in the following chapters.
The corresponding directory contains the OCX directory, which in turn contains all
the program components required for installation, and the installation programs
Secure OCX Setup_d.bat and Secure OCX Setup_en.bat (for German or English
installation of the operating system). The entire directory
OCX_FOR_SECURE_DISP_WinCC… is first copied to an installation directory.
The installation directory must be located on the same drive as the WinCC flexible
software.
If WinCC flexible is not located in the directory <C:\Programs> or <C:\Program
Files>, the setup program must be edited using an editor and rewritten to the other
directory. The following source code for the Secure OCX Setup.bat shows the
sections that may need to be changed marked in bold. This is the code for WinCC
flexible 2005.
--------------------------------------------------------------------------------------------------------------
@echo off
color 3f
cls
echo *---------------------------------------------------------------------------*
echo * Automatic install routine to install the Secure OCX program *
echo * Only works, when SIMATIC WinCC Flexible 2005 is installed in directory *
echo * C:\program files\Siemens. *
echo * Otherwise cancel with Strg”+“C” and adapt the file *
echo * Secure OCX Setup_en.bat (see Device Manual) *
echo *---------------------------------------------------------------------------*
echo * The following directory structure is installed on your C:\ partition: *