Messages and Diagnostics
SIWAREX FTA
7-140
Error
No.
Data and
command errors -
description
Solution
8
Reserved
9
Reserved
10
Reserved
11-
19
Action not
permitted in
weighing cycle
11
Data record transfer
or command
transfer to weighing
cycle not permitted
The data record or the command is not permitted to be activated
during the weighing cycle. Send the data or the command
outside of the weighing cycle.
The following commands are not permitted in weighing cycle:
Switch on service operation (1)
Impedance measurements (10, 11)
Zero setting-, Tare commands (21, 22, 23, 24)
Print log (31, 32, 33, 34)
Deleting, formatting MMC (72, 73, 74, 75)
Start commands (100, 101, 102)
Abort (108)
Emptying on / off (109, 118)
Delete total, statistic (113, 114, 115, 116)
12
Command cannot
be executed
because the
previous command
is not finished yet.
A new command cannot interrupt the execution of the current
command. Activate the command after the current command has
finished executing.
This message is generated in the following instances:
Start command (100, 101, 102) while log output to printer is still
running
Repeated setting of the data records with default values (8)
within one second
Execute one of the following commands if the required stand-still
has not occurred:
Continue a weighing procedure (103, 104), Adjustment
commands (3, 4, 5, 6, 7), Tare command (22, 23, 24),
Print log (31, 32, 33, 34)
13
Command or data
transfer not allowed
in this operating
status
A new command cannot be executed in this operating status.
14
Continue command
(104, 104) not
possible
The command can no longer be executed since a scale error
caused implausible switching points.
15
Set value in cycle
not plausible
The set value to be used is greater then the maximum set value
in DR23.
16
Instruction is not
permitted
(digital load cell)
Instruction is not permitted for operation with digital load cell
17
Instruction is not
permitted
(analog load cell)
Instruction is not permitted with analog load cell
18
Reserved
19
Reserved