4.4 Quick operating reference
ALARM
System on
Fault
Isolation
Detector
test mode
FC330A
Remote alarm
fault / off
Alarm horn
fault / off
System fault
Remote alarm
active
Alarm delay
off
Premises
manned
hm
0
del
789
456
12
3
F1
F2
ok
Start/
Stop
Reset
Acknowledge
(spare)
Silence/resound horn
to scroll
alarm messages
On ’alarm’:
to silence buzzer
to start alarm organization
to silence horn
to reactivate horn
Start operating press keystart/stop’
enter password (4 digits + ok) or turn key
SELECT: 1. ENabling
(main menu) 2. DISabling
3. INFO polling
4. other functions
ENabling: 1. detector ’zone’
(1.1) 2. detector ’element’
3. ConTrol ’zone’
INFO: 1. system status
(3) 2. event memory/alarm counter
3. configuration/user text
4. configuration zone/line/LON
FUNCTIONS: 1. function
(4) 2. system TEST
3. printout
4. configuration
to printout lists (only if printer is connected)
to set time + date
to prolong mode ’manned’
to set detectors in mode ’detector test’
to initiate ’horn test’, ’lamp test’ etc.
only for service engineer
to view actual system status
to view event memory + alarm counter
only for service engineer
to enable isolated system parts, such as
detector zones, individual detectors (elements)
alarm horn, remote transm. (RT)
alarm contacts (control), printer
main menu
On menu navigating:
to enter password
to select menu option
On ’fault’:
to silence buzzer
On ’alarm’:
to reset system after the
fire event is cleared
On ’fault’:
to reset certain fault
messages
Menu operating:
to start menu navigating
(main menu)
to stop operating
On ’alarm’:
to poll physical address
On menu navigation:
to go one level back
On data input:
to delete character(s)
enter ’1’ + ’ok’
select ’1...3’ + ’ok’ to open submenu
DISabling: 1. detector ’zone’
(2.1) 2. detector ’element’
3. ConTrol ’zone’
enter ’2’ + ’ok’
select ’1...3’ + ’ok’ to open submenu
for temporary disabling of system parts, such as
detector zones, individual detectors (elements)
alarm horn, remote transm. (RT)
alarm contacts (control), printer
enter ’3’ + ’ok’
select ’1...4’ + ’ok’ to open submenu
enter ’4’ + ’ok’
select ’1...4’ + ’ok’ to open submenu
Stop operating press keystart/stop’
On ’alarm’ and mode
’manned’:
to cancel alarm delay in
case of emergency
On workdays:
to set system to mode
’manned’ in the morning
Key lock (if provided):
to get operating access