FX30 Factory Configuration
Rev 4 March 2019 79 41110030
AirVantage Management Services Polling
Mode
The default FX30 configuration setting for AVMS Polling Mode is 60 minutes. The
AT command to change the setting is AT+WDSC=3,x where x is the number of
minutes. See the WP8548/WP75xx/WP76xx/WP77xx AT Command Reference
for more information.
Note: If you are experiencing issues with your FX30 not automatically checking in with
AVMS, then query the AV Polling rate using AT+WDSC?
If the result is +WDSC: 3,0 then AV Polling is disabled. Please enable polling using
AT+WDSC=3,60 to set the polling rate to 60 minutes.
AirVantage Management Services User
Agreements
The default FX30 configuration for AVMS User Agreements is “Disabled” for the
following modes:
• AVMS connection
• Package download
• Package install
• Device reboot
• Application uninstall
The AT command to change the user agreements is AT+WDSC. See the
WP8548/WP75xx/WP76xx/WP77xx AT Command Reference for more
information.
UART Settings
The default FX30 configuration setting for UART1 is for AT Command Service,
and UART2 is disabled. The AT command to change the setting is AT!MAPUART.