Functional Description
AP05
Date: 22.08.2022 Art. No. 90885 Mod. status 108/22 Page 11 of 50
Bit
Meaning
Value = 0
Value = 1
3
bc03_DisplayRange
Normal display area
Extended display area
4
bc04_GuardingBit
is mirrored in
StatusWord
is mirrored in
StatusWord
5
bc05_ErrorAck
-
Acknowledge error
6
bc06_Reserved
ever 0
-
7
bc07_Reserved
ever 0
-
8
bc08_Reserved
ever 0
-
9
bc09_TargetValueActive
-
Activate target value
10
bc10_Reserved
ever 0
-
11
bc11_Led1Green
Release via LED
parameters
required
Deactivate LED
Activate LED
12
bc12_Led1Red
Deactivate LED
Activate LED
13
bc13_Led2Green
Deactivate LED
Activate LED
14
bc14_Led2Red
Deactivate LED
Activate LED
15
bc15_LedBlinking
Deactivate LED
Activate LED
Table 4: ControlWord in Absolute Position operating mode
3.1.1.4 StatusWord in Absolute Position operating mode
The Status Word shows the current status of the AP05.
The designation of the individual bits of the StatusWord as well as their meaning:
Bit
Meaning
Value= 0
Value= 1
0
bs00_DirIndicationCW
Target value can be
reached counterclockwise
or in negative direction
Target value can be
reached clockwise or in
positive direction
1
bs01_DirIndicationCCW
Target value can be
reached clockwise or in
positive direction
Target value can be
reached counterclockwise
or in negative direction
2
bs02_CalibrationExecuted
No calibration is currently
being carried out
A calibration is currently
being carried out
3
bs03_Reserved
ever0
-
4
bs04_GuardingBit
mirrored from ControlWord
mirrored from ControlWord
5
bs05_TargetWindowReached
Target window is not
reached
Target window is reached
6
bs06_Deviation
Deviation
Actual value <= target
value
Deviation
Actual value > target value
7
bs07_GeneralError
No error
There is an error
8
bs08_Reserved
ever0
-
9
bs09_IncMeasurement
Increment measurement is
deactivated
Increment measurement is
activated
10
bs10_TargetValueState
Target value is not
activated
Target value is activated

Table of Contents

Other manuals for Siko AP05

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siko AP05 and is the answer not in the manual?

Siko AP05 Specifications

General IconGeneral
BrandSiko
ModelAP05
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals