Functional Description
AP05
Date: 22.08.2022 Art. No. 90885 Mod. status 108/22 Page 20 of 50
All error memories and error counters are deleted when the factory settings are restored
(see chapter 3.5.3).
3.5.2.2 Presentation
In presentation mode, specific parameters and a fixed set point (850) are set and validated.
So, the mode of operation of the device can be presented without the need of specifying a set
point via an interface. As soon as the device is restarted or process data are exchanged with
an IO-Link master, the presentation is finished.
3.5.3 Restore factory settings
There are various options for restoring the factory settings of the device:
Access
Coding
Factory settings are restored
Manual
CODE
(see chapter 4.5.7)
011100
all parameters
Load Default
(see chapter 4.5.6)
A
all parameters
Interface
SystemCommands
(see chapter 5.3)
130 (82h)
all parameters
Table 16: Access to factory settings
3.5.4 Operation hours counter
Various operating hours counters are in operation in the AP05.
3.5.4.1 General operating hours counter
Detects the time during which the device is sufficiently supplied via the connection line and
is therefore in operation. Operating mode and state are irrelevant. This counter cannot be
deleted or reset.
General characteristics
EEPROM
yes
Unit
Hours
Value range
0 … 87600 (10 years)
Memory accuracy
10 min
IO-Link
Data type
-
Access
-
Index
-
-
-
Data Storage
-

Table of Contents

Other manuals for Siko AP05

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siko AP05 and is the answer not in the manual?

Siko AP05 Specifications

General IconGeneral
BrandSiko
ModelAP05
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals