Date: 22.08.2022 Art. No. 90885 Mod. status 108/22 Page 48 of 50
Value
Name
Type
Comment
20498 (5012h)
Battery low
Warning
Charging state "critical"
25376 (6320h)
Parameter error
Error
Data memory faulty,
IO-Link Spec.
Table 31: EventCodes
5.6 ErrorCodes
Value
1
st
Byte
Value
2
nd
Byte
Name
Comment
80
xx
Error Code
IO-Link Spec.
V1.1.2 Annex D
00
Device application error, no details
11
Index not available
12
Subindex not available
20
Service temporarily not available
21
Service temporarily not available, local control
22
Service temporarily not available, device control
23
Write access denied
30
Parameter value out of range
31
Parameter value above limit
32
Parameter value below limit
33
Parameter length overrun
34
Parameter length underrun
35
Function not available
36
Function temporarily not available
40
Invalid parameter set
41
Inconsistent parameter set
82
Application not ready
81
xx
Vendor specific error code
Table 32: Error codes