EasyManua.ls Logo

Siko AP05 - Keycalibration; Keyincremental

Siko AP05
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
AP05
Date: 22.08.2022 Art. No. 90885 Mod. status 108/22 Page 35 of 50
4.5.2 KeyCalibration
General characteristics
EEPROM
yes
Unit
-
Value range
0 ... 1
Default
1
IO-Link
Data type
UnsignedInteger8 / Bool
Access
rw
Index
88
Sub-index
0
Data Storage
yes
Display
Menu
chPAr \ OPIO \ CAEn
Parameter selection
Value
Display
Description
0
O
Functions disabled via key
1
ON
Functions enabled via key
4.5.3 KeyIncremental
General characteristics
EEPROM
yes
Unit
-
Value range
0 ... 1
Default
1
IO-Link
Data type
UnsignedInteger8 / Bool
Access
rw
Index
89
Sub-index
0
Data Storage
yes
Display
Menu
chPAr \ OPIO \ ICn
Parameter selection
Value
Display
Description
0
O
Functions disabled via key
1
O
Functions enabled via key

Table of Contents