EasyManuals Logo

Simrad CP50 User Manual

Simrad CP50
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
CP42/50/52 Miscellaneous menu Chapter 8
86
ENT
Load Setup for Wind display
Setup for Wind:
Damping level: MEDIUM
Relative wind scale: NORMAL
Wind angle offset: 000°
Show wind speed as: RELATIVE
Wind speed unit: METERS/SECOND
The settings
available for
each
function are
described on
the next
page.
Go to the function you wish to change
+/-
Toggle between settings, or
0-9
key in new figure
ENT
Confirm entry and return to Wind display
Damping level can be set to
LOW, MEDIUM
or
HIGH
. The higher
level the more steady and slow reacting reading.
Relative wind scale can either be set to
NORMAL
(0-180°)or
MAGNIFIED
(0-60°).
Wind angle offset can be from 0 to 360°.
Show wind speed as
TRUE
or
RELATIVE.
Wind speed unit can be either
METERS/SECOND, KNOTS,
KILOMETERS/HOUR
or
MILES/HOUR.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad CP50 and is the answer not in the manual?

Simrad CP50 Specifications

General IconGeneral
BrandSimrad
ModelCP50
CategoryGPS
LanguageEnglish

Related product manuals