CP42/50/52 Miscellaneous menu Chapter 8
86
ENT
Load Setup for Wind display
Setup for Wind:
Damping level: MEDIUM
Relative wind scale: NORMAL
Wind angle offset: 000°
Show wind speed as: RELATIVE
Wind speed unit: METERS/SECOND
The settings
available for
each
function are
described on
the next
page.
Go to the function you wish to change
+/-
Toggle between settings, or
0-9
key in new figure
ENT
Confirm entry and return to Wind display
Damping level can be set to
LOW, MEDIUM
or
HIGH
. The higher
level the more steady and slow reacting reading.
Relative wind scale can either be set to
NORMAL
(0-180°)or
MAGNIFIED
(0-60°).
Wind angle offset can be from 0 to 360°.
Show wind speed as
TRUE
or
RELATIVE.
Wind speed unit can be either
METERS/SECOND, KNOTS,
KILOMETERS/HOUR
or
MILES/HOUR.