401925/C
41
Ifnecessary,enabletheread-outintheDisplayOptionsdialogbox.
8Ifpossible,useanotherinstrumenttoverifythattheinformationprovidedbythe
EK80iscorrect.
9Fillintheresulttables.
Result
DatagramPortBaudrateTalkerID
Requirements
Results
Speeddataisprovidedanddisplayed.
Therelevantcommunicationparametersarerecorded.
Dateandsignature:
Relatedtopics
Customeracceptanceform,page46
Secondaryprocedures,page47
Verifyingthecommunicationwiththemotion
referenceunit(MRU)
Theinformationfromamotionreferenceunit(MRU)(normallyheave,rollandpitch
information)isimportedintotheEK80toincreasetheaccuracyoftheechodata.The
communicationwiththesensoristested.Thistaskisonlyapplicableisyouareusingan
externalmotionreferenceunitonyourEK80.
Prerequisites
TheEK80isinstalledasspeciedintheEK80Installationmanual.
•ThesensorisconnectedtoacommunicationportontheEK80.Thesensoristurned
onandinnormaloperation.
•Theinterfaceportissetupwiththecorrectcommunicationparameters.
•YouarefamiliarwithNMEAandotherrelevantdatagramformats.
•Youknowhowtosetuptheparametersforserialandlocalareanetwork(LAN)
communication.
•Allrelevantvesseldrawings,installationreportsand/ormeasurementresultsare
available.
•TheEK80systemisturnedonandoperatesnormally.
TestingtheEK80operationalfunctionality