AllrelevantexternalsensorsareconnectedtotheEK80.Thesensorsareturned
onandoperatenormally.
Thevesselisberthed.
TherelevantperipheralsystemisconnectedtotheEK80ProcessorUnit.
TheconnectionhasbeenmadeusingaserialorEthernetcommunicationport.
Alltherelevantcommunicationparametershavebeendened.
Theperipheralsystemisturnedon,andittransmitsdata.
Neithertoolsnorinstrumentsarerequired.
Procedure
1OpentheSetupmenu.
2OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.Thisdialogboxcontainsanumber
ofpagesselectedfromthemenuontheleftside.
3OntheleftsideoftheInstallationdialogbox,selectI/OSetup.
4Makesurethateachinputportisfunctional.
aSelecttherelevantcommunicationport.
bSelectMonitortoopenthePortMonitordialogbox.
cMakesurethatthereisdatatrafcontheinputport(shownintheRxDatabox).
Inordertoseethisdatatrafc,theperipheralsystemmustbeturnedon,and
transmittinginformationtotheEK80.
dIfyouareunabletoseeanydatatrafconthecommunicationport,wesuggest
thefollowing:
1Makesurethattheperipheralsystemhasbeenturnedon.
2Makesurethattheperipheralsystemisinfacttransmittinginformation.
3Makesurethatthecablehasbeenproperlyconnected.
4Makesurethatyouhaveconnectedtheperipheralsystemtothe
communicationportthatyouareobserving.
eSelectOKtoclosethePortMonitordialogbox.
5Makesurethateachoutputportisfunctional.
aSelecttherelevantcommunicationport.
bSelectMonitortoopenthePortMonitordialogbox.
cMakesurethatthereisdatatrafcontheoutputport(shownintheTxData
box).