Table 8-7 Lithium battery BMS fault codes (Continued)
Fault code
Description
Fault code
Description
0x206
Discharge of Low Temperature-Second
Level
0x30D Low SOC-Third Level
0x306
Discharge of Low Temperature-Third
Level
0x10E
High SOC-First Level
0x107
Charging at Low Temperature-First
Level
0x20E
High SOC-Second Level
0x207
Charging at Low Temperature-Second
Level
0x30E
High SOC-Third Level
0x307
Charging at Low Temperature-Third
Level
0x20F
BMS Communication Fault-Second
Level
0x108
Discharge at High Temperature-First
Level
0x210
Abnormal Communication with
Charger-Second Level
8.4 BASIC TROUBLE SHOOTING
Table 8-8 Table of faults and solutions
Fault Cause Solution
Power indicator not ON
Machine is not powered on.
The key switch is in the OFF position.
The emergency stop button on the platform controller or
the ground controller is pressed.
The platform controller is malfunctioning or failure to
power off the platform controller after downloading
program.
The ground controller is malfunctioning or failure to
power off the ground controller after downloading
program.
CAN equipment offline
Inspect whether the leads of the power supply and
communication are inserted properly and reliably.
Inspect whether all pins of the Deutsch plugs for the
platform controller and ground controller connecting
cables are wired according to the drawing.
Inspect whether the platform controller plug or the plug
of the connecting cable between the platform controller
and ground controller are in good contact.
Inspect whether the platform controller is
malfunctioning.
Inspect whether the Deltatech plug of ground controller
is firmly and correctly connected.
Tilt alarm always
sounding while in level
status
The level switch is not
connected or has trouble.
Inspect whether the level switch is inserted properly and
firmly.
Inspect whether the level switch is malfunctioning.
Platform failed to be
leveled
Electrical failure
Check the wiring and control program
Function solenoid problem
Check the function solenoid, adjust the pressure or
replace the function solenoid
Cylinder or pipeline leakage
Check the pipeline and connectors for leakage.
Check the cylinder or its seal for leakage.