CONTROL SYSTEM
TB20J Plus Maintenance Manual 143
© Feb. 2023
Fig 4 LANGUAGE Interface
3. Select 中文 or English through
and , and press
and hold
for 3s to complete language setting.
4. Press
successively to return to the main inter-
face, and power off the machine as required.
11.5 TEST-RUN INFORMATION
1. Press on the main interface to enter CONFIGU-
RATION interface.
2. According to the navigation diagram of display inter-
face, enter TEST-RUN INFO interface by pressing
, and .
Fig 5 TEST-RUN INFO Interface
Sensor Calibration
This operation is to calibrate sensors other than the
weighing sensor (its calibration method will be de-
scribed in detail in the subsequent weight calibra-
tion ).
If the machine is equipped with a dual-channel sen-
sor, only 1 channel is needed to be selected for max-
imum value and minimum value calibration.
1. On the TEST-RUN INFO interface, select Sensor
Calibration through
and and enter SENSOR
CALIBRATION interface by pressing
.
Fig 6 SENSOR CALIBRATION 1 interface
Fig 7 SENSOR CALIBRATION 2 interface
Fig 8 SENSOR CALIBRATION 3 interface
2. On the SENSOR CALIBRATION interface, select
the position to be calibrated through
and
(there will be the flashing before the selected op-
tion), press and hold
for 3s to complete the cali-
bration (the icon before the selected option is