Y070.020/GB Page 65
Operation instructions
SIPOS 5 PROFITRON, HiMod
8
Maintenance, inspection, service
8 Maintenance, inspection, service
8.2 Lubrication intervals and lubricants
8.2.1 Lubrication intervals
Perform service or inspection after approx. 8 years (refer to chapter 8.1).
After 50 operating hours or 1 year, regrease coupling shaft A, if available, at the greasing nipple.
For output shaft form A, ensure that the valve stem is greased separately!
These intervals are valid for normal load. When exposed to more intensive loads, the maintenance
intervals are reduced accordingly.
Actuators in high temperature version – additional order code T09 - must be inspected every two
years by the SIPOS-Service and wear parts are must be replaced!
Whenever the covers and hoods are removed, the seals must be inspected for damage. Replace
and regrease if necessary.
8.2.2 Lubricant assignment and quantity:
Actuator type
2SA5.1/2
2SA5.3/4 2SA5.5/6/7/8
2SB551/2 2SB553/4 part-turn actuator
2SC501/2/3/4,2SC551/2 2SC505/6,
2SC553/4
-
Gear oil Lubricant quantity 760 cm
3
1600 cm
3
2400 cm
3
Filling level
1
max. 46 mm max. 58 mm 23 – 27 mm
Lubricant
2
Klübersynth GH 6 – 220 N ( Klüber)
3
or
Alphasyn PG 220 Polyglycol (Castrol), Be-
rusynth EP 220 (Bechem), Panolin EP gear
synth 220 (Kleenoil).
MOBIL SHC Gear
220
3
,
4
(refer to
indication on the
equipment)
Grounding connec-
tions (inside)
Lubricant quantity 1 cm
3
Lubricant
2
Vaseline (DAB 10) V10
Other lubrication
points
5
Lubricant quantity 50 cm
3
Lubricant
2
Grease AR1 (ZEPF)
Output shaft form
A
6
(2SA5)
Lubricant quantity 2 cm
3
Lubricant
2
Commercial ball bearing grease
Thrust unit for 2SB5... Virtually maintenance-free
(The recommendations for the actuators should also be observed
here.)
Part-turn unit for 2SC5...
Part-turn gearbox for 2SG5...
■
The manufacturer‘s instructions and relevant regulations are to be observed when handling and
disposing of lubricants. Technical information concerning lubricants is available on request.
■
Before using an alternative new lubricant (other than that fi lled in the factory), the gear units and
gear parts have to be rinsed and cleaned (avoid mixing of the oils).
1
Measured from the lubricant surface to the exterior of the housing at oil fi lling screw.
2
Ambient temperature range -20 – +60 °C.
3
Lubricant used in factory.
4
Filling of the actuators:
– until approx. October 2004 with Klüber Syntheso D 220 EP,
– until approx. October 2011 with Mobilgear SHC XMP 220.
5
e.g. sealing rings, gear systems, bearings, feather keys, uncoated surfaces etc.
6
if available.