• Ensure after the installation that the installed linear actuator can
be moved inside the elongated hole (2) of the hinge head (1).
F ig. 39
6.7.4 Mechanical pinch protection
Adhere to the larger installation measures for the use of a linear
actuator with pinch protection. († Data sheets for linear actuator
and accessories in the appendix).
6.7.5 Master-slave actuator function
The master-slave actuator function features an additional actuator
(slave actuator) which is connected to the Matrix MAX6 linear actua-
tor via a jack plug (e. g. Matrix MAX1 or MAX3). Note the following
during the connection:
• Only one linear actuator with a power supply voltage of 24 V DC
may be connected.
• When both actuators (master actuator and slave actuator) run
together, the total power may not exceed 6 A
Connect slave actuator to Matrix MAX6
• Special tools required:
– Special tool from the manufacturer (part no. 0125322)
1 Check sealing ring of jack plug (arrow) and the jack plug of the
slave actuator for damage.
Fig. 40
56