EasyManua.ls Logo

Skope ReFlex Underbench - Page 23

Skope ReFlex Underbench
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
SKOPE Reflex Underbench Fridge and Freezer
Electronic Controller
Service Manual
Door not self-closing or door
gasket leaking
Open the door and let it go. If it does not close on
its own, repair the self-closing mechanism.
If required, replace the door gasket.
30
Excessive automatic
defrosting
The system is automatically
defrosting too frequently.
Evaporator probe
Either:
Measure the probe resistance to make sure it is
within the range.
Compare the probe’s temperature with the known
temperature, using an external trusted
thermometer.
Evaporator motor or fan
Check that the fan motors are working and the fan
blades are not damaged.
Controller
The controller may be reading incorrectly and
need replacing.
Blocked drain
Clear the blockage with a wet vacuum.
Clear the debris to prevent a blockage.
Defrost setting too high
Reload the correct parameters using the SCS
Connect Field app.
Compressor or gas leak Swap the cartridge.
Table 6: Alarms (continued)
Code Description Possible root cause Action

Related product manuals