SKOPE Reflex Underbench Fridge and Freezer
Electronic Controller
Service Manual
• Door not self-closing or door
gasket leaking
• Open the door and let it go. If it does not close on
its own, repair the self-closing mechanism.
• If required, replace the door gasket.
30
Excessive automatic
defrosting
The system is automatically
defrosting too frequently.
• Evaporator probe
Either:
• Measure the probe resistance to make sure it is
within the range.
• Compare the probe’s temperature with the known
temperature, using an external trusted
thermometer.
• Evaporator motor or fan
• Check that the fan motors are working and the fan
blades are not damaged.
• Controller
• The controller may be reading incorrectly and
need replacing.
• Blocked drain
• Clear the blockage with a wet vacuum.
• Clear the debris to prevent a blockage.
• Defrost setting too high
• Reload the correct parameters using the SCS
Connect Field app.
• Compressor or gas leak • Swap the cartridge.
Table 6: Alarms (continued)
Code Description Possible root cause Action