Page #73 background imageLoading...
Page #73 background image
73
SJ20 238886ABA
Section 5 – ProceduresBattery Maintenance
E-0-0-8
Battery temperature out of range. Algorithm
dependent.
Cool or warm batteries as needed.
Check temperature sensor and connections.
This error automatically clears once the condition has
been corrected.
E-0-1-1
Charge disabled by external command
Charger has been disabled by an external controller
over the CANbus network.
This error automatically clears once the command has
been removed.
E-0-1-2
Reverse polarity
Battery is connected the wrong way around. Check the
battery connections.
This error automatically clears once the condition has
been corrected.
E-0-1-3
Battery does not take current
Check for an electrical component or loose connection
between the charger and the battery.
When charging lithium batteries, make sure the charger
is properly connected to the battery and battery
management system.
This error automatically clears once the charger is
disconnecting DC or AC.
E-0-1-9
Hardware build does not support software
version
The charger hardware does not support the new
software version.
Existing SW is left running. Contact Delta-Q
Technologies.
E-0-2-0
No active algorithm selected
Reprogram the charger with its original software,
algorithms, and settings.
Use the wrench button to select the correct algorithm if
still available on the charger.
The problem clears automatically when an available
algorithm is set on the charger, as default.
E-0-2-1
High battery voltage while charging. Algorithm
dependent. Typically 2.8V/cell.
When already charged, some new batteries may exhibit
this error.
Disconnect the battery connection and wait for the
battery voltage to fall. Reconnect the batteries to see if
the condition reoccurs.
Check battery size and condition. Batteries in poor
condition, with a high internal resistance, may cause
this error. New batteries, if charged when already full,
may also cause this error. Disconnect and reconnect the
batteries a few times.
Check the battery voltage and cable connections.
This error automatically clears once the condition has
been corrected.

Table of Contents