75
SJ20 238886ABA
Section 5 – ProceduresBattery Maintenance
E-0-3-2
CAN Heartbeat Lost
An error was detected with the CAN heartbeat
communications with a registered node being guarded.
Check the networked CANbus device(s) for correct
functioning.
This alarm does not display or get logged on the
charger but does appear on the CAN bus via an
emergency message.
E-0-3-6
Battery temperature sensor is missing or
shorted
Check sensor connections.
The charger behavior when this fault occurs can be
configured. OEMs may contact Delta-Q Technologies for
more information.
This error automatically clears once the condition has
been corrected.
E-0-3-8
Fan will not turn
(Fan-equipped models only)
Check fan connections.
Check to make sure the fan turns freely and is not
obstructed.
This error automatically clears once the condition has
been corrected.
E-0-4-0
Fan voltage pulled low
(Fan-equipped models only)
Check to make sure the fan turns freely.
E-0-4-5 Battery disconnected
Battery disconnected
Reconnect the battery or check the wiring
E-0-4-6 Invalid PDO Length
Check to make sure all PDOs are valid length.
This error automatically clears once the condition has
been corrected
E-0-4-7 Platform overvoltage alarm
A battery or some other source has been connected to
the charger that exceeds the hardware’s design limits.

Table of Contents

Other manuals for Skyjack SJ20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ20 and is the answer not in the manual?

Skyjack SJ20 Specifications

General IconGeneral
BrandSkyjack
ModelSJ20
CategoryLifting Systems
LanguageEnglish

Related product manuals