EasyManua.ls Logo

SMA sunny home manager - Page 16

SMA sunny home manager
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
You will find a list of supported energy meters with D0interface in the planning
guidelines "SMASmartHome" at www.SMA-Solar.com.
Recommended resolution: at least 10Wh
Information: for the function Limiting of active power feed-in, the energy meters with
D0interface must have a resolution of at least 1Wh.
Energy meter with S0interface in accordance with DINEN62053-31, classA:
Energy meters with an S0interface must output cumulative values of all line conductors
at the S0interface. If necessary, contact the manufacturer of the energy meter.
Bidirectional meters with an S0interface must be equipped with twoS0interfaces.
Recommended pulse length: at least 20ms
Recommended pulse rate: 1000 pulses per kWh
Information: for the function Limiting of the active power feed-in, energy meters with
an S0interface must have the following minimum pulse rates:
At a maximum allowed grid feed-in of more than 1500W: at least 250 pulses per
kWh
At a maximum allowed grid feed-in of less than 1500W: at least 500 pulses per
kWh
Router
The use of a router that supports DHCP is recommended.
All network components used must support the IGMP protocol, minimum version3 (IGMPv3).
Other Devices
The following devices can be controlled via a radio-controlled socket. Suitable load profiles are
already available for these devices in Sunny Portal.
Heat pump StiebelEltronWWK300
Heat pump TecalorTTA300
The load profiles apply for all devices of the Stiebel Eltron WWK electronic range and the Tecalor
TTA electronic range. Refer to the manufacturer manual for information on how to connect the
devices.
Smart appliances
The following household devices have been fitted with the energy management data protocol and
have been tested with SMASmartHome (status: June 2015, additional devices in preparation).
Stiebel Eltron heat pumps in conjunction with the Stiebel Eltron ISGweb and the EMI software
module:
Integral systems:
LWZ 303, 403 (Integral/SOL) from manufacture date 08/2008
LWZ 304, 404 (SOL)
Air/water heat pumps:
2 Safety
SMA Solar Technology AG
Installation ManualHoMan-IA-en-2016

Table of Contents

Other manuals for SMA sunny home manager

Related product manuals