11 Decommissioning
11.1 Decommissioning the SunnyHomeManager
Procedure:
Disconnecting the SunnyHomeManager from the voltage supply
Removing the cables and dismounting the SunnyHomeManager
Disconnecting the SunnyHomeManager from the voltage supply
1. If the SunnyHomeManager is supplied with voltage via the plug-in power supply unit:
Pull the plug-in power supply unit out of the outlet.
Unplug the DC plug of the plug-in power supply unit from the terminal Power of the
SunnyHomeManager.
2. If the SunnyHomeManager is supplied with voltage via a top-hat rail power supply unit:
3.
Danger to life due to electric shock
Lethal voltages are present at the connection point of the utility grid.
Disconnect the connection point from the utility grid via the disconnection device (e.g. in
the distribution board).
Remove the connection plug of the top-hat rail power supply unit from the pin connector
on the SunnyHomeManager.
Removing the cables and dismounting the SunnyHomeManager
1. Unplug the connection plugs of the energy meters from the pin connectors on the
SunnyHomeManager.
2. Unplug the network cable from the network terminal of the SunnyHomeManager.
3. Unplug the other end of the network cable from the router.
4. If the SunnyHomeManager is mounted on the wall, push the SunnyHomeManager upwards
and remove it from the wall.
5. If the SunnyHomeManager is mounted on a top-hat rail, remove the SunnyHomeManager
from the top-hat rail as follows:
Press the SunnyHomeManager down. Tilt
the lower edge of the
SunnyHomeManager forwards and
remove from the top-hat rail.