3.2.1 Environment
The product must not be operated, installed, stored or transported in the
following conditions. Potential malfunction or damage to the product may
occur if these instructions are disregarded.
This product is not designed for clean room usage. The pump and
ventilating fan inside the product generate particles.
Location that is exposed to steam, salt water or oil.
Location that is exposed to dust or powder material.
Location that is exposed to corrosive gas, organic solvent, chemical
solution, or flammable gas. (The product is not explosion-proof.)
Location where the ambient temperature is out of the following range:
During transportation or storage: -15 to 50°C (No water or circulating
fluid in the piping.)
During operation Air cooling type: -20 to 45°C
Water cooling type: 2 to 45°C
When the ambient temperature or circulating fluid temperature is
10
o
C or below, use the circulating fluid specified in "3.2.2 Operation
at low ambient temperature or low circulating fluid temperature".
Location where condensation forms on the inside electrical parts.
Location that is exposed to direct sunlight or heat radiation.
Location that is near heat sources and poor in ventilation.
Location that is subjected to abrupt changes in temperature.
Location that is subjected to strong electromagnetic noise (intense
electric field, intense magnetic field, or surges).
Location that is subjected to static electricity, or conditions where static
electricity can discharge to the product.
Location that is subjected to strong high frequencies raditation.
Location that is subjected to potential lightening srtike.
Location at altitude of 3000m or higher (except during product storage
and transport). Refer to below for details.
Location where the product is affected by strong vibrations or impacts.
Keep the product upright on a rigid and flat floor which can resist
the weight of the product, and take measures to prevent the
product from tipping over. Improper installation may cause water
leakage, tipping, damage of the product or injure the operator.
Keep the ambient temperature of the product between -20 to 45
o
C.
Operation out of this ambient temperature range may cause a
malfunction of the product. Operating the product in an
environment temperature of 45
o
C may reduce the heat
discharging efficiency of the heat exchanger and the safety device
may function, resulting in the product operation stoppage.
The installer/end user is responsible for carrying
out an acoustic noise risk assessment on the equipment after
installation and taking appropriate measures as required.
Do not set up the product in places possibly exposed to leakage of
flammable gas. Should any flammable gas stay around the
product, the product may cause a fire.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks HRSH Series and is the answer not in the manual?

SMC Networks HRSH Series Specifications

General IconGeneral
BrandSMC Networks
ModelHRSH Series
CategoryChiller
LanguageEnglish

Related product manuals