CALIBRATION
1. Raise the lift to the alignment working height with no vehicle. Set the lift down on the locks.
2. The RCP xture must be assembled prior to use. The components consist of:
Aluminum bar
Large and Small Target
3. Attach the small target to the single leg bracket.
4. Attach the large target to the double leg bracket.
5. Clean the targets using glass cleaner and a soft lint free towel. DO NOT USE A SHOP TOWEL.
RELATIVE CAMERA POSITIONING (RCP)
The purpose of the camera calibration procedure is to measure the cameras’ positions relative to each other.
This allows the aligner to make accurate measurements between the left and right sides of the vehicle. For
this reason the alignment program will not run until a valid RCP has been performed. The unit is shipped from
the factory with valid RCP factors and it is not necessary to perform RCP unless a Camera is exchanged or
RCP has been lost such as a crashed hard drive with no back up.
Tools needed: Fixed-Length Target Fixture with two targets.
1. Raise the empty lift to working height (no vehicle). Close the garage door to block any stray daylight.
2. Prepare the Calibration Fixture.
3. Clean the two targets on the xture, according to the user manual. Use a glass cleaning uid and a soft
cloth. Make sure that the glass is free from grease and dirt.
4. Power on the Alignment System.
5. From the calibration menu click on the RCP icon to begin the process.
6. Slide the turntables to the outboard position. Place the calibration bar on the right rack rail, with the small
target on the outside of the front turntable, and the large target towards the rear center of the rail.
7. Click on <NEXT> when done.