HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
83
7.3.5 Peak Shaving Mode
Used to limit the maximum power priority purchased from the
grid.The maximum purchasing power can be set in this mode.
When the system preferentially buys more power from the grid
than the set value,The battery starts discharging and stabilizes
the system power at the set value.
Application:
Peak Shaving Mode allows the grid to supply power to the load
first. Applicable to the occasions where electricity price is
charged according to electricity consumption and the occasions
where the power grid is weak. In the weak grid situation,
batteries start only when the load power exceeds a certain value,
which reduces the maximum power of the connecting point
and prolongs the battery life.
7.3.6 Off-grid Mode
When the SOC of the battery is sufficient and can be discharged,
it is preferred to use the battery in off-grid load mode (even if
the power grid exists). After the battery enters the state of
power loss, it will be transferred to the power grid or generator
for load, and the battery will be charged.
1.AC Source
Grid charge: After the battery enters the state of power loss, it is
transferred to the grid to carry the load and charge the battery.
DG charge: After the battery enters the state of power loss, it is
transferred to the generator to carry the load and charge the
battery.
2.AC Charge
AC Charge: The sum of the power input to the power grid or
generator after battery loss and when charging the battery.
Note
When AC Source is set to DG charge, the generator can
be started through Genset Mode in dry contact Control.
EODO: EPS Discharge Depth
EPSbuffer: Safety Buffer
Application:

Related product manuals