4 Safety & Warnings
__________________________________________________________________________________
2. SAFETY & WARNINGS
2.1 Safety
1
Read this manual carefully before operating the equipment and follow its
instructions.
2
Installation, operation and maintenance should be in strict accordance
with this manual, national codes and good practice.
3
Installation or operation not performed in strict accordance with these
instructions will void manufacturer’s warranty.
4
Disconnect all power inputs before servicing the soft-starter and/or the
motor.
5
After installation, check and verify that no parts (bolts, washers, etc) have
fallen into the starter.
6
During shipping, the soft-starter might have been roughly handled,
therefore, it is recommended to initialize the soft-starter by connecting
supply voltage prior to operating the soft-starter with a motor
2.2 Attention
1
This product was designed for compliance with IEC 947-4-2 for class A
equipment.
2
RVS-DX 8 - 170 are UL and cUL approved. RVS-DX 210 - 1100 are
designed to meet UL and cUL requirements.
3
Use of the product in domestic environments may cause radio
interference, in which case, the user may be required to employ
additional mitigation methods.
4
Utilization category is AC-53a or AC53b, Form 1. For further information,
see Technical Specification
2.3 Warnings
1
Internal components and PCBs are at mains potential when the RVS-DX
is connected to mains. This voltage is extremely dangerous and will
cause death or severe injury if contacted.
2
When RVS-DX is connected to mains, even if control voltage is
disconnected and motor is stopped, full voltage may appear on starter’s
output and motor’s terminals.
3
The starter must be grounded to ensure correct operation, safety and to
prevent damage.
4
Check that Power Factor capacitors and overvoltage devices are not
connected to the output side of the soft starter.
If PF capacitors are used, they must be connected on the line side of the
RVS-DX .
If a main contactor is used in combination with RVS-DX, the capacitors
must be disconnected from RVS-DX when contactor is open.
5
Do not interchange line and load connections
The company reserves the right to make any improvements or modifications to its products without
prior notice.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solcon RVS-DX Series and is the answer not in the manual?

Solcon RVS-DX Series Specifications

General IconGeneral
BrandSolcon
ModelRVS-DX Series
CategoryController
LanguageEnglish

Related product manuals