for S6 Series Grid Inverter
Version 1.0, Release Date: 08,2023
Applicable models
S6-GC25K-US
S6-GC33K-US
S6-GC36K-US
S6-GC40K-US
S6-GC50K-US
S6-GC60K-US
S6-GC-30K-LV-US

Table of Contents

Other manuals for SOLIS S6 Series

Questions and Answers

  • N
    Nicholas LunaAug 27, 2025
    What to do if SOLIS S6 displays OV-ILLC (1052 DATA:0000)?
    • H
      Heather ByrdAug 27, 2025
      If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.
  • K
    Kathryn SuarezSep 10, 2025
    What does 'OV-Vbatt' mean on my SOLIS Inverter and how to solve it?
    • J
      Joseph YoungSep 10, 2025
      The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
  • A
    Andrew JonesAug 27, 2025
    What does ARC- FAULT (1041 DATA:0000) mean on SOLIS S6 and how to fix it?
    • C
      Carol LittleAug 27, 2025
      The ARC- FAULT (1041 DATA:0000) error on your SOLIS Inverter indicates a potential arc fault. Start by verifying that all connections within your PV system are tight. If further adjustment is needed, arc fault settings can be changed in advanced settings.
  • S
    Sarah ThompsonSep 23, 2025
    What does Grid disturbance 02 mean on SOLIS S6?
    • B
      Barry WeberSep 23, 2025
      A 'Grid disturbance 02' error on your SOLIS Inverter suggests a problem with the power grid or AC cable connection. Check if the grid is seriously distorted and ensure the AC cable is reliably connected.
  • J
    Jason FosterSep 18, 2025
    What to do if SOLIS S6 Inverter shows over DC injection error?
    • C
      Charles GreenSep 18, 2025
      If your SOLIS Inverter is showing an over DC injection error, restart the inverter.
  • J
    Jason TorresSep 12, 2025
    What does 'OV-Vbackup' mean on my SOLIS S6 and how to fix it?
    • T
      Theresa BarnesSep 12, 2025
      The 'OV-Vbackup' error on your SOLIS Inverter indicates an over-voltage issue with the backup. Check whether the backup port wiring is normal. If the issue persists, restart the system.
  • K
    Kelsey FigueroaSep 22, 2025
    What to do if my SOLIS Inverter displays Fan Alarm?
    • A
      Anne DiazSep 22, 2025
      If your SOLIS Inverter shows a Fan Alarm, check if the internal fan is working correctly or if it is jammed.
  • K
    Kimberly SanchezSep 23, 2025
    What does OV-Vbatt mean on my SOLIS Inverter?
    • D
      darrell15Sep 23, 2025
      The OV-Vbatt error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Measure the battery voltage at the inverter connection point. If the problem continues, contact your battery manufacturer.
  • K
    Kristin BradyAug 29, 2025
    What does LmtByEPM mean on my SOLIS Inverter?
    • L
      lauren70Aug 29, 2025
      If your SOLIS Inverter is showing 'LmtByEPM', confirm the inverter is connected to an external EPM/meter to prevent reverse current. Also, check if the inverter is controlled by an external third-party device and verify if the power setting of the inverter power control is limited. You may also need to verify settings in section 6.6.7 and check your meter readings.
  • M
    Madeline ReynoldsAug 29, 2025
    What does 12Power-FAULT mean on SOLIS Inverter?
    • A
      Adam AguirreAug 29, 2025
      If your SOLIS Inverter displays '12Power-FAULT (1038 DATA:0000)', check for current leakage to ground, verify your grounding, and ensure all wires are in good condition and not leaking current to ground.

SOLIS S6 Series Specifications

General IconGeneral
Number of MPPTs2
THDi<3%
DC SwitchYes
Max. AC Output Power6000W
Rated AC Output Power6000W
Max. AC Apparent Power6000VA
Rated Grid Voltage230V
Grid Voltage Range180V-280V
Rated Grid Frequency50Hz/60Hz
Grid Frequency Range45-55Hz / 55-65Hz
ProtectionDC Reverse-Polarity Protection, AC Short-Circuit Protection
Operating Temperature Range-25°C to 60°C
CoolingNatural Cooling
CommunicationWiFi/GPRS

Related product manuals