What does BatName-FAIL mean on SOLIS S6 Inverter?
- Jjennifer04Aug 30, 2025
If your SOLIS Inverter displays 'BatName-FAIL', confirm that the battery model selection is consistent with the actual battery you are using.

What does BatName-FAIL mean on SOLIS S6 Inverter?
If your SOLIS Inverter displays 'BatName-FAIL', confirm that the battery model selection is consistent with the actual battery you are using.
What does Fan Alarm mean on SOLIS S6?
If your SOLIS Inverter displays 'Fan Alarm', check if the internal fan is working correctly or if it is jammed.
What to do if my SOLIS S6 Inverter shows OV-G-V01 error?
If your SOLIS Inverter displays OV-G-V01 error, ensure the power grid is working normally and the AC cable is properly connected. If the issue continues after these checks, restart the system to see if the fault clears.
What does OV-Vbatt mean on my SOLIS Inverter?
The OV-Vbatt error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Measure the battery voltage at the inverter connection point. If the problem continues, contact your battery manufacturer.
How do I resolve grid overfrequency on my SOLIS S6 Inverter?
In the event of a grid overfrequency error on your SOLIS Inverter, check the grid connection to ensure it is correct, and wait for the grid frequency to return to normal.
What does 'BatName-FAIL' mean on my SOLIS Inverter and how to resolve it?
If your SOLIS Inverter displays 'BatName-FAIL', confirm whether the battery model selection is consistent with the actual one.
What should I do if my SOLIS S6 shows UN-Vbatt?
If your SOLIS Inverter displays UN-Vbatt, restart the system to see if the fault clears. If the issue persists, it's recommended to contact the manufacturer's customer service for further assistance.
How to fix BatName-FAIL error on SOLIS S6 Inverter?
If your SOLIS Inverter shows BatName-FAIL, confirm that the battery model selection in the settings is consistent with the actual battery model connected.
What does Fan Alarm mean on my SOLIS S6, and how can I fix it?
If your SOLIS Inverter displays Fan Alarm, check to see if the internal fan is working correctly or if it is jammed.
What to do if my SOLIS Inverter displays OV-DC01 (1020 DATA:0001) error?
If your SOLIS Inverter displays OV-DC01 (1020 DATA:0001), check if the PV voltage is abnormal. Restart the system and confirm if the fault continues.
| Number of MPPTs | 2 |
|---|---|
| THDi | <3% |
| DC Switch | Yes |
| Max. AC Output Power | 6000W |
| Rated AC Output Power | 6000W |
| Max. AC Apparent Power | 6000VA |
| Rated Grid Voltage | 230V |
| Grid Voltage Range | 180V-280V |
| Rated Grid Frequency | 50Hz/60Hz |
| Grid Frequency Range | 45-55Hz / 55-65Hz |
| Protection | DC Reverse-Polarity Protection, AC Short-Circuit Protection |
| Operating Temperature Range | -25°C to 60°C |
| Cooling | Natural Cooling |
| Communication | WiFi/GPRS |