JEA USER MANUAL
34 I +44 (1753) 214 500
ECO Mode Cut-In – DAY
The temperature at which the compressor will turn ON when the system is running in Day-Eco mode. If the
temperature is below this value, the compressor will remain OFF
SUPERFROST Mode Cut-Out – DAY
The temperature at which the compressor will turn OFF when the system is running in Day-Superfrost mode. The
compressor will remain ON until the temperature reaches the Cut-Out temperature.
SUPERFROST Mode Cut-In – DAY
The temperature at which the compressor will turn ON when the system is running in Day-Superfrost mode. If the
temperature is below this value, the compressor will remain OFF
Normal Mode Cut-Out – NIGHT
The temperature at which the compressor will turn OFF when the system is running in Night-Normal mode. The
compressor will remain ON until the temperature reaches the Cut-Out temperature.
Normal Mode Cut-In – NIGHT
The temperature at which the compressor will turn ON when the system is running in Night-Normal mode. If the
temperature is below this value, the compressor will remain OFF
ECO Mode Cut-Out – NIGHT
The temperature at which the compressor will turn OFF when the system is running in Night-Eco mode. The
compressor will remain ON until the temperature reaches the Cut-Out temperature.
ECO Mode Cut-In – NIGHT
The temperature at which the compressor will turn ON when the system is running in Night-Eco mode. If the
temperature is below this value, the compressor will remain OFF
SUPERFROST Mode Cut-Out – NIGHT
The temperature at which the compressor will turn OFF when the system is running in Night-Superfrost mode.
The compressor will remain ON until the temperature reaches the Cut-Out temperature.
SUPERFROST Mode Cut-In – NIGHT
The temperature at which the compressor will turn ON when the system is running in Night-Superfrost mode. If
the temperature is below this value, the compressor will remain OFF
Temperature Blind Time
The duration the JEA ignores the regulation (Air) temperature after the compressor switches ON.
Temperature Display Unit
Select the unit of temperature the JEA will display all temperature values.
F = Degree Fahrenheit
C = Degree Celsius
9.3 DEFROST
PARAMETER DESCRIPTION UNITS MIN MAX DEFAULT
dF1 Defrost Start Timer Type - rEL / aCC / Cnt rEL
dF2 Threshold For Enabling Defrost Function
°C
°F
N/A, -40
N/A, -40
40
104
N/A
dF3 Defrost Start Interval Hours N/A, 1 255 10
dF4 Defrost End Interval Minutes N/A, 1 255 15