EasyManuals Logo

Sollatek JEA Series User Manual

Sollatek JEA Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
JEA USER MANUAL
sollateksupport@sollatek.com I 39
A3+ CMYK
Compressor Protection Delay Initial Bypass Count (not congurable via the display)
The number times the JEA can be powered up with Intelligent Delay disabled. After the specied number of
power ups the delay works as per settings (Itd).
Note: For testing purpose ONLY to avoid waiting 3 minutes for Compressor to turn on.
9.6 CONDENSER CONTROL
PARAMETER DESCRIPTION UNITS MIN MAX DEFAULT
OH Condenser Temperature High Threshold
°C
°F
N/A, -40
N/A, -40
90
194
70
158
Ohd Condenser Temperature High Differential
°C
°F
1
1
130
234
5
9
SC Condenser Temperature Low Threshold
°C
°F
N/A, -40
N/A, -40
90
194
-20
-4
SCd Condenser Temperature Low Differential
°C
°F
1
1
130
234
5
9
Condenser Temperature High Threshold
The maximum temperature that turns OFF the compressor for system protection.
Condenser Temperature High Differential
The temperature differential below the Condenser Temperature High Threshold, which the JEA will revert to
normal operation
Condenser Temperature Low Threshold
The Minimum temperature that turns OFF the compressor for system protection.
Condenser Temperature Low Differential
The temperature differential above the Condenser Temperature Low Threshold, which the JEA will revert to
normal operation
Note: Only condenser control or cooler lockout can be enabled at one time.
9.7 LIGHTS CONTROL
PARAMETER DESCRIPTION UNITS MIN MAX DEFAULT
L0 Lights Regulated By Logic - AOn / ESL / Dr ESL
L1 Lights On Delay (Night To Day Mode Switch) Minutes 0 255 0
L2 Lights Off Delay (Day To Night Mode Switch) Minutes 0 255 0
L3 Lights Switch Enable - No / Yes Yes
Note: The lights will ALWAYS turn ON when the door is opened regardless of any of the settings and modes.
Lights Regulated By Logic
Select whether the state of lights will change when the controller changes Modes
Always On (AOn): Lights are ON unless the controller is in Refrigeration Failure Mode or switched OFF manually.
By ES Logic (ESL): Lights will turn ON/OFF when the controller changes from Day to Night mode and vice versa.
By Door (Dr): Lights will only turn ON when the door is open. When the door is closed the lights will turn OFF
Light ON Delay (Night to Day Mode)
The time delay between the controller switching from Night to Day mode, and the lights turning ON.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sollatek JEA Series and is the answer not in the manual?

Sollatek JEA Series Specifications

General IconGeneral
BrandSollatek
ModelJEA Series
CategoryTemperature Controller
LanguageEnglish

Related product manuals