JEA USER MANUAL
sollateksupport@sollatek.com I 41
Enable Power ON/OFF Button
Select whether the JEA can be turned OFF through the display buttons
No = Button function disabled. JEA is always on when plugged in.
Yes = Button function enables. JEA and outputs can be manually turned OFF through the display
button
Power Cut HACCP Alarm Time Threshold
The minimum duration of a power cut for the JEA to log it as an alarm.
Note: Only available on JEA versions with self-learning (JEA-xxxS model)
9.10 INITIAL PULL DOWN
PARAMETER DESCRIPTION UNITS MIN MAX DEFAULT
Pdt Initial Pull-Down Initial Temperature
°C
°F
-40
-40
40
104
25
77
Pt1 Time Before Initial Pull-Down Cut-Out (Pdo) Is Activated Hours 0 255 4
PdO Initial Pull-Down Cut-Out Value
°C
°F
-40
-40
40
104
0
32
Initial Pull-Down Initiate Temperature
The temperature, which if exceeded fat power up, will enable a pull-down.
Time Before Initial Pull-Down Cut-Out is Activated
The minimum time the regulation temperature must exceed the Initial Pull-Down Initiate Temperature (Pdt),
during pull-down to change the cut-out to the initial pull-down cut-out value (Pd0).
Initial Pull-Down Cut-Out Value
The cut-out temperature which will be applied during pull-down in case the regulation temperature remained
above Pdt for longer than Pt1.
Note: Defrost is disabled during Pull-down unless Allow Defrost During Initial Pull-Down (dPd) is enabled. Pull-down is also
forced when the controller is taken out of lockout mode, regardless of the temperature.
9.11 EVAPORATOR FAN MANAGEMENT
PARAMETER DESCRIPTION UNITS MIN MAX DEFAULT
Fd0 Fan Cycle With Compressor - No / Yes Yes
Fd1 Day Duty Cycle On Time Compressor Cycles Off Minutes 0 255 2
Fd2 Day Duty Cycle Off Time Compressor Cycles Off Minutes 0 255 3
Fn1 Night Duty Cycle On Time Compressor Cycles Off Minutes 0 255 2
Fn2 Night Duty Cycle Off Time Compressor Cycles Off Minutes 0 255 3
FC1 Allow Fan Management During Normal Operation - No / Yes Yes
FC2 Allow Fan Management During Eco Mode - No / Yes Yes
FC3 Allow Fan Management During Superfrost Mode - No / Yes Yes
Fd Switch Off Fan On Door Opening Event - No / Yes Yes
FH Fan Duty Cycle Override Temperature
°C
°F
0
32
90
194
15
59
FHd Fan Duty Cycle Override Temperature Differential
°C
°F
0
0
25
45
2
4
FSt Fan Minimum Stop Time Seconds 0 255 2
Fan Cycle With Compressor
Select the operation of the evaporator according to the compressor
No = Fan is ON when the compressor is OFF. If set to No, Fd1, Fd2, Fn1, Fn2, FC1, FC2 & FC3 will be ignored
Yes = Fan cycles when the compressor is OFF