JEA USER MANUAL
A3+ CMYK
40 I +44 (1753) 214 500
Light OFF Delay (Day to Night Mode)
The time delay between the controller switching from Day to Night mode, and the lights turning OFF.
Lights Switch Enable
Select whether the state of lights will change with a button press
No = Light button disabled. Lights will only turn ON/OFF with logic or if Refrigeration Failure Mode is entered
Yes = Light button enabled.
9.8 DOOR OPERATION
PARAMETER DESCRIPTION UNITS MIN MAX DEFAULT
d1 Door Open Alarm Delay Minutes 0 255 2
d2 Door Switch Malfunction Delay Delta Minutes 0 255 5
d3 Door Close Duration Compressor On Seconds 0 255 0
d4 Door Open Duration Evap Fan Off Seconds 0 255 0
d5 Door Close Duration Evap Fan On Seconds 0 255 0
Standard Door Open Operation
If the door opens and Door Opening Event (Fd0)= YES
Any Operational Mode
Fan: OFF (respecting d4)
Door Open Indicator: ON (solid)
Defrost Operation
Fan: ON
Door Open Indicator: ON (solid)
Door Open Alarm Delay
The time between the door opening and staying open, and the Door Alarm Triggering.
Door Switch Malfunction Delay Delta
The Time differential above the Door Open Alarm Delay (d1) which will trigger the Door Malfunction operation.
Door Close Duration Compressor ON
The duration for the door to remain closed after a Door Open Alarm before the compressor will turn back ON.
Door Open Duration Evap Fan OFF
The duration the door to remain open before the evaporator fan will switch OFF if Switch OFF fan on Door
Opening Event (Fd0) is set to Yes.
Door Close Duration Evap Fan Back ON
The duration the door to remain open before the evaporator fan will switch back ON if Switch OFF fan on Door
Opening Event (Fd0) is set to Yes.
9.9 POWER ON/OFF BUTTON (only editable through the JEA display)
PARAMETER DESCRIPTION UNITS MIN MAX DEFAULT
POF Enable Power ON/OFF Button - No / Yes Yes
PCt Power Cut HACCP Alarm Time Threshold Minutes N/A, 1 255 1

Questions and Answers: