Contact the service if you meet other problems not in the table.
• Check if the ground line is connected with the
inverter;
Make sure the grounding connection of the
inverter is connected and reliable.
If this fault occurs often, contact the service.
Check the grid voltage at the point of
connection of inverter.
If the grid voltage is outside the permissible
range due to local grid conditions, try to modi-
fy the values of the monitored operational limi-
ts after informing the electric utility company
rst.
If the grid voltage lies within the permitted ran-
ge and this fault still occurs, please call service.
PE wire connec-
tion fault
48
65
10 minutes
average over
voltage fault