31
Factory reset Basic
1 Press and hold programming button on motor or receiver
2 With any RTS transmitter, (io for Sonesse 40 io)
1 Cut the power twice
Press and hold programming button
10 sec in In2 sec out 2 sec out
...motor jogs and... ...aer 5 sec. ...motor jogs again
OK
Press and hold
the programming
button for 10 sec.
5 sec.
<1 sec.
Motor jogs 3 times
First aer 2 sec.
Aer 7 sec. Aer 12 sec.
OK
or
All DC RTS motors and receivers, all Li-Ion motors
The RTS motor/receiver is now reset. Start programming from beginning
The motor is now reset. Start programming from beginning
Sonesse 40 RTS/io, Sonesse (ULTRA) 50 RTS
3 sec.
- +
3 sec.
or or