7.3 SPRAY TIMING MODES
Timing modes are selected by going to the HMI sengs page and selecng the “Timing” buon.
The system will spray for a predetermined me depending on the ming mode selected. The spray controller allows
for accurate me-based control over the spray nozzle based on an external trigger signal.
When there is a start delay value of 0 sec., the spray will start immediately aer the trigger signal is sent to the 1750+,
and if the stop delay is set to 0 sec. the spray will stop immediately aer trigger signal goes low. All delay values can be
set from 0.00 to 320.00 sec., spray mes can be set to 0.01 to 320.00 sec.
SPRAY PERIOD
•
The spray period is the me the object remains under the spray nozzle or the me that it takes to dispense a dose.
This will be in me units.
START DELAY
•
The me that the system should wait between a trigger event and the start of the spray.
•
Typically, this is the distance between the sensor and the spray nozzle.
•
The start delay must always be longer than the congured minimum signal length of the trigger.
STOP DELAY
•
The me that the system should wait between the end of a trigger event and the end of the spray. Typically, this is
the distance between the sensor and the spray nozzle.
Timing settings