7.3 SPRAY TIMING MODES
Timing modes are selected by going to the HMI sengs page and selecng the Timingbuon.
The system will spray for a predetermined me depending on the ming mode selected. The spray controller allows
for accurate me-based control over the spray nozzle based on an external trigger signal.
When there is a start delay value of 0 sec., the spray will start immediately aer the trigger signal is sent to the 1750+,
and if the stop delay is set to 0 sec. the spray will stop immediately aer trigger signal goes low. All delay values can be
set from 0.00 to 320.00 sec., spray mes can be set to 0.01 to 320.00 sec.
SPRAY PERIOD
The spray period is the me the object remains under the spray nozzle or the me that it takes to dispense a dose.
This will be in me units.
START DELAY
The me that the system should wait between a trigger event and the start of the spray.
Typically, this is the distance between the sensor and the spray nozzle.
The start delay must always be longer than the congured minimum signal length of the trigger.
STOP DELAY
The me that the system should wait between the end of a trigger event and the end of the spray. Typically, this is
the distance between the sensor and the spray nozzle.
Timing settings

Other manuals for Spraying Systems AUTOJET 1750+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spraying Systems AUTOJET 1750+ and is the answer not in the manual?

Spraying Systems AUTOJET 1750+ Specifications

General IconGeneral
BrandSpraying Systems
ModelAUTOJET 1750+
CategoryControl Panel
LanguageEnglish