22
7.4 FIXED SPRAY TIME
This ming mode is used to create a delayed spray pulse for a xed predetermined amount of me. The system will
spray aer a trigger, then stops unl next trigger event occurs. For every trigger, there is a single spray event.
Set parameter value to 0.
ANTICIPATOR PRIORITY
By default, the system gives priority to the start delay, potenally resulng in a too short or a zero-ancipator me,
which may negavely impact the spray paern if the start delay is too short.
In this case, the start delay will be extended as required to provide a correct ancipator me. This is parcularly useful
when the start delay may not be known beforehand, for example when seng the ming using analog signals.
SPECIAL CASE: MULTIPLE TRIGGERS WITHOUT SPRAY OVERLAP
Occurs if the system receives mulple start events (rising edge of trigger signal) before a spray cycle is nished. If the
me delay between two successive start events (or trigger pulses) is higher than the spray me, then there is no
overlap.
Fixed spray period
Ancipator Priority
Mulple Triggers without Spray Overlap