SPECIAL CASE: MULTIPLE TRIGGERS WITH SPRAY OVERLAP
Occurs if the system receives mulple start events (rising edge of trigger signal) before a spray cycle is nished. If the
me delay between two successive start events (or trigger pulses) is lower than the spray me, then there is an
overlap of two successive spray pulses.
FIXED SPRAY TIME– WITH REPEAT SPRAY
This ming mode is used to create a connuous repeon of spray period for a xed me.
Special Case: Repeat Spray, Air Overlap: If repeat o-me <= (ancipator + follower me), the air will remain on.
Note: This can happen in both xed and Variable spray mes.
Mulple Triggers with Spray Overlap
Repeat Spray
Repeat spray, air overlap