7 Teleservice Application Framework
User Manual 194/374
START_TAG
(uint16)
BlockLength
(uint16)
Datainfo
(uint16)
Datum in sec since
1970
(uint32)
DP List
ID
(uint8)
DP List
Var ID
(uint8)
Datum
(Datum Length *
uint8)
Datainfo:
BIT 0 1
----------
0 = time triggered
1 = event triggered
2 = time or event triggered
BIT 2 3
----------
0 = no timestamp
1 = RTC
2 = user defined timestamp
BIT 4
0 = C2C Format
Binary_TC3_LE
Log File header:
----------------
LOGFILE_HEADER
LogFile;Test_Logger
LogFileFormat;5
Comment;Test log job for Test
MaxSize;10485760
Date+Time;22.11.11_13:30:53
FileInfo:
Timestamp:1
DP :00;Test
Lst:00;Engine
Var:00;EngineSpeed;Type:SINT32;Size:4;Unit:rpm
Var:01;InjectionQuantity;Type:SINT32;Size:4;Unit:mm3/H
Var:02;EnginePowerReserve;Type:SINT32;Size:4;UNIT:%
DATASTART
START_TAG
(uint16)
BlockLength
(uint16)
Datainfo
(uint16)
Datum in sec
since 1970
(uint32)
msec
(uint16)
not
used
DP ID
(uint8)
DP
List ID
(uint8)
DP
List
Var ID
(uint8)
Datum
(Datum
Length *
uint8)
Datainfo:
BIT 0 1
----------
0 = time triggered
1 = event triggered
2 = time or event triggered
BIT 2 3
----------
0 = no timestamp
1 = RTC
2 = user defined timestamp
BIT 4
1 = TC3 Format