EasyManua.ls Logo

STW TC1 - Page 205

STW TC1
374 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Teleservice Application Framework
User Manual 205/374
Parameter
Range
Description
opcn_LogJobName
maximum
MAX_DL_NAME_LENGTH
pointer to the log job name
opcn_DatapoolName
maximum
MAX_DP_NAME_LENGTH
pointer to the data pool name
opcn_ListName
maximum
MAX_DP_NAME_LENGTH
pointer to the variable list name
opcn_VariableName
maximum
MAX_DP_NAME_LENGTH
pointer to the variable name
opcn_Logic
maximum
MAX_DL_LOGIC_LENGTH
pointer to the logical operator like '<=', '>=', '!='
and '=='
ou32_Hysteresis
uint32
pointer to the hysteresis of the variable we
expect to log
ou32_Threshold
uint32
pointer to the logging threshold for the variable
we expect to log
opcn_Concatenation
maximum
MAX_DL_CONC_LENGTH
pointer to concatenation options like 'AND', 'OR'
and 'EXOR'
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn; // D-BUS connection instance
charn acn_myNameString[128]; // Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128]; // Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128]; // Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512]; // Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval; // Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048]; // Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
Function executed without error, event condition was set successfully