EasyManua.ls Logo

STW TC1 - Page 211

STW TC1
374 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Teleservice Application Framework
User Manual 211/374
Parameter
Range
Description
ou32_LogFolderSize
if folder size reaches this level, older logs will be
deleted
opcn_LogFileExtension
maximum
MAX_DL_NAME_LENGTH
Extension of the logger file.
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn; // D-BUS connection instance
charn acn_myNameString[128]; // Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128]; // Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128]; // Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512]; // Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval; // Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048]; // Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
Function executed without error
activating log job successfully
C_COM
D-Bus communication error
C_UNKNOWN_ERR
Wrong value or NULL pointer
C_NOACT
Error occurs because:
logger job name
start/stop flag invalid,
data logger configuration does not exist
no data logger running,
DLC file corrupt
logger already initialized
can not initialize data pool configuration

Table of Contents