Chapter 4 Basic Administrative Tasks 41
You can check the status and turn the Locator LED on and off from either the
superuser or ALOM prompt.
TABLE 4-4 lists the commands.
Alarm Status Indicators
The dry contact alarm card has four LED status indicators that are supported by
ALOM. They are located vertically on the bezel (
FIGURE 4-1). Information on the
alarm indicators and dry contact alarm states is provided in
TABLE 4-5. For more
information on alarm indicators, see the Advanced Lights Out Manager CMT v1.2
Guide, 819-6672-10
.
TABLE 4-4 Locator LED Commands
Prompt Status Turn On Turn Off
Superuser # /usr/sbin/locator # /usr/sbin/locator -n # /usr/sbin/locator -f
ALOM sc> showlocator sc> setlocator on sc> setlocator off