78 Netra T2000 Server Administration Guide September 2006
To Perform a Mirrored Disk Hot-Swap
Operation
1. Verify which hard drive corresponds with which logical device name and physical
device name.
See “Slot Numbers and Device Names for Non-RAID Disks” on page 67.
If the Disk Status is FAILED, then the drive can be removed and a new drive
inserted. Upon insertion, the new disk status should be OK and the volume should
be RESYNCING.
2. To confirm a failed disk, type the following command:
For example:
This example indicates that the disk mirror has degraded due to a failure in disk
c0t2d0.
Note The logical device names might appear differently on your system,
depending on the number and type of add-on disk controllers installed.
3. Remove the hard drive, as described in the server service manual.
There is no need to issue a software command to bring the drive offline when the
drive has failed.
4. Install a new hard drive, as described in the server service manual.
The RAID utility automatically restores the data to the disk.
# raidctl
# raidctl
RAID Volume RAID RAID Disk
Volume Type Status Disk Status
--------------------------------------------------------
c0t1d0 IM DEGRADED c0t1d0 OK
c0t2d0 FAILED

Table of Contents

Other manuals for Sun Microsystems Netra T2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Netra T2000 and is the answer not in the manual?

Sun Microsystems Netra T2000 Specifications

General IconGeneral
BrandSun Microsystems
ModelNetra T2000
CategoryServer
LanguageEnglish

Related product manuals