Chapter 6 Managing Disk Volumes 79
5. To check the status of a RAID rebuild, type the following command:
For example:
This example indicates that RAID volume c0t1d0 is resynchronizing.
If you issue the command again once synchronization has completed, it indicates
that the RAID mirror is finished resynchronizing and is back online:
For more information, see the raidctl(1M) man page.
▼ To Perform a Nonmirrored Disk Hot-Swap
Operation
1. Verify which hard drive corresponds with which logical device name and physical
device name.
See “Slot Numbers and Device Names for Non-RAID Disks” on page 67.
Ensure that no applications or processes are accessing the hard drive.
# raidctl
# raidctl
RAID Volume RAID RAID Disk
Volume Type Status Disk Status
--------------------------------------------------------
c0t1d0 IM RESYNCING c0t1d0 OK
c0t2d0 OK
# raidctl
RAID Volume RAID RAID Disk
Volume Type Status Disk Status
--------------------------------------------------------
c0t1d0 IM OK c0t1d0 OK
c0t2d0 OK