SUNFAR C300 5
C300 series of non-sensor current vector-control inverter manual
Operation Status
Out freq., Out current, Out voltage, Motor speed,
Setting freq., Temperature of Module, PID setting,
Feedback value, Analog O/I, ect.
Display
Fault details
Recently six faults recorded, output freq., setting freq.,
output current, output voltage, DC voltage and module
temperature
Protection/Warning Functions
Over current, over voltage, under current, under
voltage, thermal relay, overheating, short circuit, out
voltage would be short of the phase, The parameters
of motor is abnormal, Main contactor can’t attract,
Internal memory faults, ect.
Ambient temperature: -10 ~+50℃℃
Ambient humidity: under 90%
Ambient atmosphere: indoors (non-corrosive,
non-inflammable, non-oil, non-fog etc.)
Environmental Conditions
Altitude is lower than 1000m
Enclosure rating is IP20
Configuration
Cooling system is in the cooling mode.
Installation
Hanging

Table of Contents